Through our partnership with Nationwide Boiler, ADCO has capabilities of supplying you with rental boilers from 40 horsepower to 75,000 lb/hr from our shop in Bessemer, AL.  Call us today for your rental boiler requirements! 

24 Hour Service, 7 Days a Week:  (800) 292-3891

 
BOILER SIZEDESIGNPRESSUREFUELTRAILER MOUNTPICTURE
40 HORSEPOWERFIRETUBE150 PSI DESIGNGAS / #2 OILYES 
60 HORSEPOWERFIRETUBE150 PSI DESIGNGAS / #2 OILYES 
100 HORSEPOWERFIRETUBE150 PSI DESIGNGAS / #2 OILYES, BOX Trailer CLICK HERE
100 HORSEPOWERFIRETUBE150 PSI DESIGNGAS / #2 OILYESCLICK HERE
125 HORSEPOWERFIRETUBE150 PSI DESIGNGAS / #2 OILYESCLICK HERE
200 HORSEPOWERFIRETUBE150 PSI DESIGNGAS / #2 OILYES 
350 HORSEPOWERFIRETUBE150 PSI DESIGNGAS / #2 OILYES, FEED TANK ONLY 
500 HORSEPOWERFIRETUBE150 PSI DESIGN OR 200 PSIGAS / #2 OILNO, BUT CAN ACCOMODATE 
600 - 800 HORSEPOWERFIRETUBE150 PSI DESIGNGAS / #2 OILYES 
30,000 TO 70,000 LBS/HRWATERTUBEFROM 150 - 600 PSIGGAS / #2 OILYES - BOILER ONLY 

 

TYPICAL TRAILER MOUNTED RENTAL BOILER FROM ADCO:

RENTAL BOILER

Rental is mounted on a trailer with complete boiler room components.  Description is as follows: 

Boiler

bulletU.L. Gas train
bulletRegulator up to 8 psi inlet provided
bulletBlowdown piping and valves
bulletRelief valves mounted and piped
bulletFlame safeguard system
bulletControl Circuit Transformer
bulletSmall stack
bulletPre-piped Steam Header valve (flanged connection)
bullet480 Volts required

Boiler Feed Unit

bulletDuplex System (two pumps)
bulletMake-up feed water valve
bulletPre-wired to Pump control on boiler
bullet480 Volts Required
bulletPre-piped feedwater piping from pumps to boiler

Chemical Feed System

bulletTank and pump furnished
bulletPre-piped to boiler
bullet120 Volts required

Blowdown Separator

bulletConnection to boiler blowdown piping required
bulletAfter Cooler supplied
bulletWater line connection required

Responsibilities of Contractor/Owner

bulletProvide proper chemical treatment of boiler while in operation or out of operation
bulletFurnish Gas pressure Regulator if pressure exceeds 8 psi
bulletAll Electrical connections to equipment as required
bulletAll Mechanical Connections as required
bulletAll Electrical disconnections as required for Pick-up
bulletAll Mechanical disconnections as required for Pick-up
bulletProper maintenance of equipment including daily and monthly recommendations (ie: blowdown, water treatment, etc…)

 

 

 

ADCO Corporate Headquarters
3657 Pine Lane
Bessemer, AL 35022
Phone: (205) 428-2326
Fax:     (205) 428-2395
Watts:  (800) 292-3891
E-Mail: adco@adcoboiler.com
ADCO - Huntsville location
104 Lowry Street
Huntsville, AL 35805
Phone: (256) 536-5951
Fax:     (256) 534-5552
Watts:  (800) 239-5063
E-Mail: dselles@adcoboiler.com
ADCO - Mobile location
6215 Rangeline Road #220
Theodore, AL 36582
Phone: (251) 443-7011
Fax:     (251) 443-7021
Watts:  (800) 435-7273
E-Mail: dthompson@adcoboiler.com
ADCO - Baton Rouge location
6032 "D" Fieldstone Drive
Baton Rouge, LA 70809
Phone: (225) 753-0823 
Fax:     (225) 752-7711 
Watts:  (800) 222-7815
E-Mail:
jwillis@adcoboiler.com

ADCO-Jackson, MS        202 East Government St Brandon, MS 39042  Phone: 601-825-4180    Fax: 601-825-4180       Watts: 800-292-3891          E-Mail: mcox@adcoboiler.com