ADCO COMPANIES, LTD.

ADCO Boiler Company

Home

 

 

BurnerMate TSBenefits

bulletAccurate Fuel-Air Ratio Control
bulletFuel Saving Oxygen Trim
bulletElectrical Energy Saving Variable Speed Drive (VSD)
bulletEasy to Use Touch Screen Operation and Commissioning
bulletRemote Monitoring via Standard Web Browser
bulletIntegrated Flame Safeguard

[Technical Information]

The BurnerMate TS Boiler Management System is a combined boiler control, flame safeguard and monitoring system with a touch screen operator interface. The BurnerMate TS is a full scope control package, that assures safe and efficient boiler control with undivided responsibility.

Fuel-Air Ratio Control

bulletIndependently Controlled Fuel and Air Servo Actuators - save fuel by accurately positioning fuel valves and air damper according to load
bulletFlue Gas Oxygen Trim - is used to continuously adjust (trim) the fuel-air ratio
bulletVariable Speed Fan Combustion Air Flow Control - minimizes damper pressure drop related fan power usage
bulletReal Time Boiler Efficiency Display - allows the boiler operator to instantly identified inefficiencies and potential operational problems
bulletSafety - Flue gas temperature and oxygen are monitored. Low flue gas oxygen trips the burner after an adjustable time delay
bulletSingle Point Positioning Control - is field selectable when a simpler installation is desired. The Link Trim Actuator may be mounted in-line with the air damper linkage to provide oxygen trim functions.

Boiler Auxiliary Control (separate module)

bulletFeedwater Valve Control - drum level and steam flow sensor inputs allow the controller to respond properly during substantial load swings
bulletDraft Damper Control - "GAP" PID and firing rate feedforward control features assure stable draft even during load changes
bulletTwo Auxiliary Servo Controls - are available for Flue Gas Recirculating (FGR) or other load dependent devices
bulletEconomizer Monitoring - Sensor inputs are provided to monitor water and flue gas in and out of the economizer

Flame Safeguard Protection

bulletFlame Safeguard - provides burner sequencing, ignition and flame monitoring
bulletUV or IR Flame Scanners - are applied based on the application
bulletCurrent Burner Operation Status includes - Flame signal, sequence of operation, diagnostic and "First Out" cause of lockout messages
bulletOptional Historical Burner Data inlcudes - last six lockout conditions, number of burner cycles and burner run time hours
bulletAuxiliary Device Interlock - boiler room fresh air dampers and fuel oil pump call of operation is included

Touch Screen Operator Terminal

bullet10 or 6 Inch Display Sizes - 10.4" TFT 256 color VGA 640 x 480 pixel LCD or 5.7" CSTN 256 Color QVGA 320 x 240 pixel LCD
bulletPassword Protection - user configurable options and parameters, external commissioning tools are not required
bulletReal Time & Historical Trending - is a standard feature, optioanl extended data collection allows historical alarm and event data to be exported to MS Excel
bulletX/Y Plots - for intuitive fuel-air curve display and commissioning

Advanced External Communications

bulletIntranet Network - Ethernet connection is available for Building Automation System (BAS), SCADA system or standard internet browser communication
bulletTelephone Modem (optional) - allows communication to a remote user over standard analog telephone lines
bulletRS-485 Modbus Interface - is available to communicate to an external flame safeguard that is existing or supplied by others

Advanced Communication

 

Communication
Internet, Web Site Access

A standard WEB Browser provides remote monitoring and operation. Custom Software is not required. Historical alarm and event data can be imported to spreadsheet applications such as MS Excel

Intranet Communication

The ethernet communication port is easily assigned an IP address and connected to a facility wide network. Remote monitoring, control and data collection is available via a standard WEB Browser. Building Automation Systems and SCADA Systems are interfaced via industry standard MODBUS Ethernet communication

Touch Screen Operator Interface Terminal

Monitor and control boiler operation, setpoints, and process data from one convenient display. Commissioning activities are laid out in an easy to follow step by step procedure, eliminating the need for knowledge of controller menus and programming languages

DCS-III Programmable Controller

The DCS-III is a state-of-the-art boiler-focused programmable logic controller. The large I/O quantity, small sub-panel foot print, intuitive "Blockware", redundant memories, and built-in industry standard communications allows the DCS-III to be integrated into complex boiler control systems with a minimum number of external components

 

ADCO Corporate Headquarters
3657 Pine Lane
Bessemer, AL 35022
Phone: (205) 428-2326
Fax:     (205) 428-2395
Watts:  (800) 292-3891
E-Mail: adco@adcoboiler.com
ADCO - Huntsville location
104 Lowry Street
Huntsville, AL 35805
Phone: (256) 536-5951
Fax:     (256) 534-5552
Watts:  (800) 239-5063
E-Mail: dselles@adcoboiler.com
ADCO - Mobile location
6215 Rangeline Road #220
Theodore, AL 36582
Phone: (251) 443-7011
Fax:     (251) 443-7021
Watts:  (800) 435-7273
E-Mail: dthompson@adcoboiler.com
ADCO - Baton Rouge location
6032 "D" Fieldstone Drive
Baton Rouge, LA 70809
Phone: (225) 753-0823 
Fax:     (225) 752-7711 
Watts:  (800) 222-7815
E-Mail:
jwillis@adcoboiler.com

ADCO-Jackson, MS        202 East Government St Brandon, MS 39042  Phone: 601-825-4180    Fax: 601-825-4180       Watts: 800-292-3891          E-Mail: mcox@adcoboiler.com